Search
Home About HONGFA News Center Products & Services Support Careers CSR
You are here:Products & Services >> Automotive Relay & Module > HFKD Print Print
Products & Services
Product List
Signal Relay
Power Relay
Automotive Relay & Module
Latching Relay
Hermetically Sealed Relay
Relay Socket
Power Module
Industrial Relay
Low-voltage Devices
Contactors
New Products
Relay Choosing
Product Service
Product Update



Links
Download Adobe Reader
 

PDF   Compare  
AUTOMOTIVE RELAY
Part Number:HFKD
ˇńMicro miniature 
ˇńSingle & double contact version available 
ˇńChange-over contact version 
ˇńSilent double relay available 
ˇńRoHS & ELV compliant

 
Typical Applications  
Power doors & windows, Door locking systems, Seat adjustment, Seatbelt prevention device, Immobilizers, Sunroof motor control

Characteristics
Contact Type: 1C (Single), 2C (Double)
Voltage Drop (initial): Typ.: 50mV (at 10A)(1)
Max.: 250mV (at 10A)(1)
Max. Continuous Current: 25A (85ˇć, 1h)(2)
Max. Switching Current: 25A
Max. Switching Voltage 40VDC(3)
Min. Contact load 1A 6VDC
Electrical Endurance: See "CONTACT DATA"
Mechanical Endurance: 1ˇÁ107OPS 300OPS/MIN
Insulation Resistance: 100M¦¸ (500VDC)
Dielectric Strength: between contacts: 500VAC(4)
between coil & contacts: 500VAC (4)
Operate Time (at nomi. volt.): Typ.: 3ms(at nomi. vol.)
Max.: 10ms (at nomi. vol.)
Release Time (at nomi. volt.): Typ.: 1.3ms (5)
Max.: 10ms (5)
Ambient Temperature: -40ˇć to 85ˇć
Vibration Resistance: 10Hz to 55Hz 1.5mm DA (6)
55Hz to 200Hz 98m/s2(6)
Shock Resistance: 294m/s2(6)
Terminal Type: THT  
Construction: Plastic sealed
Unit Weight: Single relay: Approx. 5g
Double relay: Approx. 10g
Note: 1) Equivalent to the max. initial contact resistance is 100m¦¸ (at 1A 6VDC).
2) For NO contacts, measured when applying 100% rated votage on coil.
3) See "Load limit curve" for details.
4) 1min, leakage current less 1mA.
5) The value is measured when voltage drops suddenly from nominal voltage to 0 VDC and coil is not paralleled with suppression circuit.
6) When energized, release time of NO contacts shall not exceed 1ms, when non-energized, release time of NC contacts shall not exceed 1ms, meantime, NO contacts shall not be closed.
7) Since it is an environmental friendly product, please select lead-free solder when welding. The recommended soldering temperature and time is (250ˇŔ3)ˇć , (5ˇŔ0.3)s.
Coil Data
ˇˇNominal Voltage: 12VDC
ˇˇPick-up Voltage: Standard:Operating voltage is 60% of the nominal voltage
Low-voltage:Operating voltage is 48% of the nominal voltage
ˇˇDrop-out Voltage: Standard:Release voltage is 8% of the nominal voltage
Low-voltage:Release voltage is 7% of the nominal voltage
ˇˇCoil Power: 0.56W,0.81W
Contact Data


Outline Dimensions, Wiring Diagram and Pc Board Layout


Ordering Information


Related Products
Legal Statement | Contact us | Download Center | Site Map