Scroll image to enlarge

HFUC5-40C(AC DC Coil)

Industry IEC Contactors(AC DC Coil)

HFUC5-C series

We are here to help! Contact us if you have an inquiry or question.


Certificates:

Product Characteristics

Optimized structure, compatible with other industrial contactors
Optimized materials, excellent resistance to abnormal heat
Optimized arc extinguishing system, better arc extinguishing effect for breaking load current
Long electric endurance under heavy load (AC-4 utilization category).
Abundant auxiliary contact blocks, can be freely combined 
Suitable for harsh environments.

Technical Parameters

Main 
Product SeriesHFUC5
Product or Component TypeContactor
Device short name HFUC5-40
Contactor application

Motor control 

Resistive load

Utilisation category

AC-3

AC-4

AC-1

Poles description3P
[Ue] Rated operational voltage Power circuit: ≤ 690 V AC 50/60Hz
[Ie] Rated operational current 40 A (at ≤60 °C) at ≤ 400 V AC AC-3 for power circuit
60 A (at ≤60 °C) at ≤ 690 V AC AC-1 for power circuit
[Us] Control circuit voltage Voltage (V)(AC/DC):  24-60   100-250
Code:                BNE     KUE 
Complementary 
Motor power kW

11 kW at 220/230 V AC 50/60 Hz (AC-3)

18.5 kW at 380/400 V AC 50/60 Hz (AC-3)

30 kW at 660/690 V AC 50/60 Hz (AC-3)

Motor power hp

3 hp at 110…120 V AC 50/60 Hz for 1 phase motors

5 hp at 200…208 V AC 50/60 Hz for 1 phase motors

7.5 hp at 220…240 V AC 50/60 Hz for 1 phase motors

10 hp at 200…208 V AC 50/60 Hz for 3 phases motors

15 hp at 220…240 V AC 50/60 Hz for 3 phases motors

30 hp at 440…480 V AC 50/60 Hz for 3 phases motors

40 hp at 550…600 V AC 50/60 Hz for 3 phases motors

Pole contact composition3 NO
[Ith] Conventional free air thermal current 

60 A (at ≤60 °C) for power circuit

10 A (at ≤60 °C) for signalling circuit

[Icw] Rated short-time withstand current 

320 A ≤40 °C - 10 s for power circuit

720 A ≤40 °C - 1 s for power circuit

72 A ≤40 °C - 10 min for power circuit

165 A ≤40 °C - 1 min for power circuit

Associated fuse rating

10 A gG for signalling circuit conforming to IEC 60947-5-1

63 A gG at ≤ 690 V coordination type 2 for power circuit

Average impedance1.5 mΩ - Ith 50 Hz for power circuit
[Ui] Rated insulation voltage 

Power circuit: 690 V conforming to IEC 60947-4-1

Power circuit: 600 V UL Certified

Signalling circuit: 690 V conforming to IEC 60947-5-1

Signalling circuit: 600 V UL Certified

Overvoltage category III
Pollution degree3
[Uimp] Rated impulse withstand voltage 6 kV conforming to IEC 60947
Mechanical durability5 M cycles
Electrical durability1.0 M cycles 40 A AC-3 at Ue ≤ 400 V
Control circuit typeAC/DC
Coil technologyWith built-in suppressor module
Control circuit voltage limits

0.85 Usmin...1.1 Usmax  (-40…60 °C): operational 

0.1 Usmax...0.75 Usmin  (-40…60 °C): drop-out 

Inrush power in VA150VA (at 25 °C)
Inrush power in W150W (at 25 °C)
Hold-in power consumption in VA5VA (at 25 °C)
Hold-in power consumption in W5W (at 25 °C)
Operating time

Power circuit: 40...60 ms closing, 18...60 ms opening

Signalling circuit (NO): 40...60 ms closing, 18...60 ms opening

Signalling circuit (NC): 32...55 ms opening, 22...65 ms closing

Maximum operating rate

Electrical: 400 cycs/h

Mechanical: 1800 cycs/h 

Connections - terminals

Power circuit: screw clamp terminals 1 2.5…35 mm² (AWG 14…2)- cable stiffness: flexible without cable end

Power circuit: screw clamp terminals 2 2.5…16 mm² (AWG 14…6) - cable stiffness: flexible without cable end

Power circuit: screw clamp terminals 1 2.5…25 mm² (AWG 14…4) - cable stiffness: flexible with cable end

Power circuit: screw clamp terminals 2 2.5…16 mm² (AWG 14…6) - cable stiffness: flexible with cable end

Power circuit: screw clamp terminals 1 2.5…35 mm² (AWG 14…2) - cable stiffness: solid without cable end

Power circuit: screw clamp terminals 2 2.5…25 mm² (AWG 14…4) - cable stiffness: solid without cable end

Control circuit: screw clamp terminals 1 1…4 mm² (AWG 18…12) - cable stiffness: flexible without cable end

Control circuit: screw clamp terminals 2 1…4 mm² (AWG 18…12) - cable stiffness: flexible without cable end

Control circuit: screw clamp terminals 1 1…4 mm² (AWG 18…12) - cable stiffness: flexible with cable end

Control circuit: screw clamp terminals 2 1…2.5 mm² (AWG 18…14) - cable stiffness: flexible with cable end

Control circuit: screw clamp terminals 1 1…4 mm² (AWG 18…12) - cable stiffness: solid without cable end

Control circuit: screw clamp terminals 2 1…4 mm² (AWG 18…12)- cable stiffness: solid without cable end

Tightening torque

Power circuit: 45 lb.in(5 N·m)- on bolt  clamp terminals - with internal hexagon socket wrench 4 mm

Control circuit: 11 lb.in(1.2 N·m)- on screw clamp terminals - with screwdriver flat Ø 6 mm

Control circuit: 11 lb.in(1.2 N·m)- on screw clamp terminals - with screwdriver Philips No 2

Auxiliary contact composition1NO1NC,2NO2NC,other combinations can be customized
Minimum switching capacity

24 V,0.1 A for C type signalling circuit

17 V,5 mA for CS type signalling circuit

Insulation resistance> 10 MΩ for signalling circuit
Mounting support

Screw

35mm or 75mm DIN Rail

Environment 
Standards

GB / T 14048.4, GB/T 14048.5,IEC 60947-4-1, IEC 60947-5-1

UL 60947-4-1, UL 60947-5-1,CSA C22.2 No. 60947-4-1, CSA C22.2 No. 60947-5-1

EN 60947-4-1 (VDE 0660 Teil 102), EN 60947-5-1 (VDE 0660 Teil 200)

BS EN 60947-4-1, BS EN 60947-5-1

Product certificationsCCC,UL(cULus Listed) ,VDE,CE,UKCA
IP degree of protectionIP20 front face conforming to IEC 60529

Permissible ambient air

temperature around the device

-40…+60 °C for normal operating

+60…+70 °C with derating (for operation in the range of Us...1.1Us)

Storage: -60…+80 °C

Operating altitude0...3000 m without derating
Fire resistanceCurrent-carrying parts:850 °C conforming to IEC 60695-2-11
Height112.5 mm
Width63 mm 
Depth132 mm
Net Weight1.0 kg
Packing Units 
Unit type of package 11 box
Number of Units in Package 11 pcs
Package 1 height 14.6 cm
Package 1 width 7.2 cm
Package 1 length 12.2 cm
Package 1 weight 1.05 kg
Unit type of package 21 carton
Number of Units in Package 212 pcs
Package 2 height 18.8 cm
Package 2 width 32.5 cm
Package 2 length 41.5 cm
Package 2 weight 13.80 kg
Offer Sustainability 
REACH Regulation Conforming
EU RoHS directive Conforming
Mercury free Yes
China RoHS Regulation Conforming
RoHS exemption information Yes 
Contractual warranty 
Warranty18 months

Dimensions

HFUC5-40~65 (3P, AC/DC coil)  

AC contactor:

Interlock contactor:

 

Note: The unit is mm. The tolerance for mounting holes: ± 0.5; for other external dimensions: ± 1.5, unless otherwise specified.

 

Products of the same type
HFUC5-40C(AC DC Coil)

Industry IEC Contactors(AC DC Coil)

HFUC5-50C(AC DC Coil)

Industry IEC Contactors(AC DC Coil)

HFUC5-65C(AC DC Coil)

Industry IEC Contactors(AC DC Coil)

HFUC5-80C(AC DC Coil)

Industry IEC Contactors(AC DC Coil)

HFUC5-95C(AC DC Coil)

Industry IEC Contactors(AC DC Coil)